<LOGO>
FM Transmitter Measurement Report
Created: 2025-04-15 05-43-42
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
88.20 MHz 5/5, 51 dBuV GENE88.2
Pilot RDS Phase Difference
7.0 kHz 4.0 kHz -2 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 70 kHz 9708 0,0103
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
7,7 dBr 8,01 dBr 8,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"GENE88.2" FE50 0 (No PTY) 1 0 1 2 --:--
RT
"GENERATIONS - SKUNK - MWEN AN SA (FT. LETO & TIITOF) "
AF EON
88.2, 101.3 MHz -
FM Scope Station: 88.20 MHz, signal: 5/5 (51 dBuV) Max at: 70 kHz MIN: 12 kHz % above 76 kHz: 0,0103 Acquired: 2025/04/15 5:42:38 Total samples: 9708 Equivalent time: 0:08:05 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000
FM Scope MAX: 8,3 dBr MIN: 7,7 dBr AVE: 8,01 dBr % above 10,2 dBr: 0,0 Last value: 7,7 dBr (2025/04/15 5:42:38) Station: 88.20 MHz, signal: 5/5 (51 dBuV) 05:36 05:37 05:38 05:39 05:40 05:41 05:42 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality